Aug 14, 2024

Public workspaceUSDA LTAR Common Experiment measurement: Total suspended solids (TSS) V.2

  • Brent Dalzell1,
  • Oliva Pisani2
  • 1USDA Agricultural Research Service, Soil and Water Management Research, St. Paul, MN;
  • 2USDA Agricultural Research Service, Southeast Watershed Research Laboratory, Tifton, GA
Icon indicating open access to content
QR code linking to this content
Protocol CitationBrent Dalzell, Oliva Pisani 2024. USDA LTAR Common Experiment measurement: Total suspended solids (TSS). protocols.io https://dx.doi.org/10.17504/protocols.io.261ge5pjog47/v2Version created by Lori J. Abendroth
License: This is an open access protocol distributed under the terms of the Creative Commons Attribution License,  which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited
Protocol status: Working
We use this protocol and it's working
Created: February 21, 2024
Last Modified: August 14, 2024
Protocol Integer ID: 105314
Keywords: Long-Term Agroecosystem Research, LTAR, crops, total suspended solids, sediments, surface water, agricultural runoff, streams, subsurface flow, tile drainage, Common Experiment, USDA LTAR
Funders Acknowledgements:
United States Department of Agriculture
Grant ID: -
Abstract
Total suspended solids (TSS) refers to all the material from a well-mixed sample retained by a filter media. In the case of environmental water samples, TSS is commonly used to measure sediment in surface waters (field runoff, ditches, and streams) but can also be present in subsurface flow where macropore flow or surface inlets to tile drainage systems are present. In some cases, TSS can also include algae or other plant materials that comprise volatile suspended solids (VSS) because combustion in a muffle furnace eliminates them. The recommended method for measuring TSS includes passing a known sample volume through a pre-weighed filter and measuring the oven-dry weight of the material trapped on the filter.
Materials
Sample Analysis:
Measurement of TSS includes passing a known volume of a well-mixed sample through a pre-weighed filter and measuring the oven-dry weight of the material trapped on the filter (APHA, 2005; USEPA, 1999).

Materials:
  1. Glass fiber filters: Whatman 934-AH glass fiber filter (1.5 µm) usage is common for TSS analysis
  2. Vacuum filtration apparatus with a funnel that includes filter support
  3. Aluminum weighing dishes
  4. Forceps
  5. Drying oven
  6. Balance with a precision of 0.1 mg or better
Sample collection
Sample collection
At a minimum, collect Amount1 mg of TSS residue. At a maximum, TSS should not impede the flow rate of the filter media (slow filtration is more time-consuming but does not impact results).

Note
  • The required sample volume will vary with site and event characteristics.
  • For many environmental samples, Amount100 mL of sample solution is a reasonable starting point if using a 4.7 cm diameter filter disc.

Return samples to the laboratory TemperatureOn ice and filter them on collection day if possible.

Sample storage and preservation
Sample storage and preservation
Analyze the samples as soon as possible after collection.
Analyze
If storage is required, refrigerate the samples at Temperature4 °C or store TemperatureOn ice to minimize decomposition of solids.

Note
  • Samples should not be stored for more than seven days (APHA, 2005).
  • Samples should be at TemperatureRoom temperature for analysis.

Archiving
Archiving
Store water samples for TSS analyses until data certification (QA/QC verification) as this is common practice.

Note
Water sample storage should not exceed seven days.

Glass fiber filter preparation
Glass fiber filter preparation
1h
1h
Assemble the vacuum filtration apparatus with a new filter.
Apply the vacuum.
Rinse the filter three times with distilled water.
Wash
Maintain the vacuum for a few seconds to remove excess water, then remove the vacuum.
Using forceps, carefully remove the rinsed filter to an aluminum weighing dish.
Dry in an oven at Temperature103 °C - Temperature105 °C for 1 hour.

Store dried filters in a desiccator until needed.
Sample analysis
Sample analysis
1h
1h
Using forceps, select a prepared glass fiber filter. Weigh it and record the mass to the nearest 0.1 mg in a lab notebook.
Unless filtering the entire sample, shake it vigorously before dividing it into a volume suitable for analysis.
Select a water sample, weigh the sample + bottle mass, and record the mass in a lab notebook.
Assemble the filtration apparatus and apply a vacuum.
Pre-moisten the filter with a small volume of distilled water.
Shake the sample vigorously and pour it into the filtration apparatus funnel.
Maintain the vacuum until all sample water has passed through the filter.
Using a wash bottle with distilled water, rinse the sample bottle and sides of the filter funnel three times (for a 4.7 cm filter, each rinse should be roughly 10 ml).
Wash
Weigh the empty sample bottle and record the mass in a lab notebook.
Remove the vacuum.
Using forceps, carefully remove the filter paper and place it in a labeled and weighed aluminum weighing dish.
Dry the filter paper + sample at Temperature105 °C for 1 hour or longer, if necessary, to remove all water.

Remove the samples from the oven and immediately store them in a desiccator or weigh them. Record the mass in a lab notebook.
Store the weighed and recorded filters in a desiccator until ready for disposal.
Sample the covariate metrics (Total N (TN) and total P (TP) concentrations) concurrently.
Perform the calculations using the following formula:
Total suspended solids in a sample (mg/L) = (A-B) * 1000 / C

Note
  • A = mass of filter and weighing dish + sample residue (mg)
  • B = mass of filter and weighing dish (mg)
  • C = volume of sample (ml); (mass of bottle with sample - mass of empty bottle)

C can also be obtained directly by pouring the sample into a graduated cylinder and recording the sample volume. The *1000 term in the equation above is a conversion factor to result in final units of mg/L.

Recommendations for data collection
Recommendations for data collection
Table 1. Summary of recommendations for the collection and measurement of TSS concentration.
ABCD
AttributePreferredMinimumComments
Spatial scaleFieldPlot
FrequencyEvent-drivenEvent-drivenSample collection frequency will depend on site-specific flow chracteristics and experimental goals
Covariate metricsTN, TPTN, TP
Sample preservation and storageAnalyze on collection dayRefrigerate at 4°C or store on ice for up to 7 days
Sample analysisTotal suspended solids dried at 103-105°C
Water quantityDischarge or flow rateDischarge or flow rateCalculate TSS loads by linking this metric to the water quantity metric “flow"
Covariate metrics = other metrics to sample concurrently. TN = total nitrogen; TP = total phosphorus.

Protocol references
1) American Public Health Association (APHA), 2005. Standard Methods for the Examination of Water and Wastewater, 21st ed. Washington, DC: American Public Health Association, American Water Works Association, and Water Environment Federation.

2) NCASI Technical Bulletin No. 291, March 1977. National Council of the Paper Industry for Air and Stream Improvement, Inc., 260 Madison Ave., NY.

3) US Environmental Protection Agency (USEPA), 1999. Method 160.2, Residue, Non-Filterable (Gravimetric, Dried at 103-105°C) Methods for the Chemical Analysis of Water and Wastes (MCAWW) (EPA/600/4-79/020).
Acknowledgements
This research is a contribution from the Long-Term Agroecosystem Research (LTAR) network. LTAR is supported by the United States Department of Agriculture. The use of trade, firm, or corporation names in this publication is for the information and convenience of the reader. Such use does not constitute an official endorsement or approval by the United States Department of Agriculture or the Agricultural Research Service of any product or service to the exclusion of others that may be suitable. USDA is an equal opportunity provider and employer.