The filtered homogenate was streaked using standardized loops on Salmonella Shigella agar (selective and differential media for Salmonella and Shigella); the loops were flamed periodically to ensure sterility. This was done in duplicate. The plates were then incubated at 34°C. After an overnight incubation at 34°C, the plate with the best significant and adequate colonies was used to test for the presence of Salmonella Those colonies that were morphologically characteristic for Salmonella are gram stained: