Oct 19, 2021

Public workspace7T MRI Protocol for response to Respiratory-gated Auricular Vagal Afferent Nerve Stimulation

  • Vitaly Napadow1,
  • Roberta Sclocco1,
  • Vitaly Napadow1,
  • Roberta Sclocco1
  • 1Massachusetts General Hospital
Icon indicating open access to content
QR code linking to this content
Protocol CitationVitaly Napadow, Roberta Sclocco, Vitaly Napadow, Roberta Sclocco 2021. 7T MRI Protocol for response to Respiratory-gated Auricular Vagal Afferent Nerve Stimulation. protocols.io https://dx.doi.org/10.17504/protocols.io.9zqh75w
License: This is an open access protocol distributed under the terms of the Creative Commons Attribution License,  which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited
Protocol status: Working
We use this protocol and it’s working
Created: December 03, 2019
Last Modified: October 19, 2021
Protocol Integer ID: 30480
Keywords: auricular vagal afferent nerve stimulation, gated auricular vagal afferent nerve stimulation, gre bold scans for the stimulation condition, auricular concha, stimulation condition, area of the auricular concha, subject to respiratory, respiratory
Abstract
This is the 7T MRI protocol for a study of the subject to Respiratory-gated Auricular Vagal Afferent Nerve Stimulation in the area of the auricular concha. Scan types include: multi-echo MPRAGE and 6 GRE BOLD scans for the stimulation conditions.