Abstract
This method was developed at the FDA’s Center for Food Safety and Applied Nutrition for GenomeTrakr’s pandemic response project, monitoring SARS-CoV-2 variants in wastewater​​. Protocols developed for this project cover wastewater collection, concentration, RNA extraction, RT-qPCR detection, library prep, genome sequencing, quality control checks, and data submission to NCBI. This method provides a reagent formula required in the rapid concentration of intact viruses from wastewater using a combination of PEG precipitation and ultracentrifugation.
Materials
ReagentHydrochloric Acid (HCl)Fisher ScientificCatalog #6000710
Deionized or ultrapure water
Sterile container (e.g., 50 ml conical tube, Fisher Scientific Cat # 14-432-22, or equivalent)

Protocol materials
ReagentHydrochloric Acid (HCl)Fisher ScientificCatalog #6000710
ReagentHydrochloric Acid (HCl)Fisher ScientificCatalog #6000710
Measure Amount14.6 mL of deionized or ultrapure water into sterile container.

Slowly add Amount10.4 mL ReagentHydrochloric Acid (HCl)Fisher ScientificCatalog #6000710 , or equivalent to the water.

Safety information
This solution should be prepared under a chemical fume hood.

Store at TemperatureRoom temperature .